Some effects of exposure to exhaust-gas streams on emittance and thermoelectric power of bare-wire platinum rhodium - platinum thermocouples

George E. Glawe, Charles E. Shepard
naca-tn-3253
Aug 1954


Thermocouples were exposed to exhaust gases from the combustion of propane, 72-octane gasoline, and JP-4 fuel. Exposure increased the emissivity of the thermocouple wire, which increased its radiation error. Two methods are presented for determining the emittance of the wires. The emissivity of a clean platinum rhodium-platinum thermocouple was approximately 0.2 in the temperature range investigated, while the emittance of an exposed thermocouple coated with exhaust residue was about 0.5. The exposure caused negligible change in the thermoelectric power of the thermocouples.

An Adobe Acrobat (PDF) file of the entire report: