Influence of tube-entrance configuration on average heat-transfer coefficients and friction factors for air flowing in an Inconel tube

Lowdermilk, Warren H Grele, Milton D
August 23, 1950

A heat-transfer investigation was conducted with air flowing through an electrically heated Inconel tube having either a long-approach or a right-angle-edge entrance, an inside diameter of 0.402 inch, and a length of 24 inches over a range of Reynolds numbers up to 375,000 and average inside-tube-wall temperatures up to 2000 degrees R. Good correlation of heat-transfer data was obtained for both entrances, which substantiates work previously reported. A fair correlation of friction data was obtained for both entrances. The entrance configuration had little effect on the average heat-transfer and friction coefficients.

An Adobe Acrobat (PDF) file of the entire report: