Total-head meter with small sensitivity to yaw

Kiel, G.
naca-tm-775
1935


The total-head meter is essentially a venturi, housing a pitot tube for obtaining the total head. In yaw the flow within the nozzle is deflected, depending upon the degree of yaw, to a greater or lesser extent into the axial direction of the nozzle. After experimenting with several nozzle forms as to their suitability, the best design was finally adopted. When, with the chosen nozzle form, the total head is 0.5 entrance section diameter downstream, the instrument supplies the genuine total head at low Reynolds Numbers up to 43 degrees yaw.

An Adobe Acrobat (PDF) file of the entire report: